Equitel E451 Instrukcja Instalacji Strona 11

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 33
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 10
August 2012 – Ed.1.2
EQUITEL – E451 Technical manual
Page 7
1.8 Factory default values recovery
To recover the system factory default values such as network configuration, access password, working mode,
audio parameters…please keep pressed the recovery button for 6 seconds (
in Figure 4).
1.9 Input contact connector
The input contact is “normally open” between the 2 pins male connector terminals (
in Figure 4), with the
following pin-out:
Pin Signal Description
1 IN+ Input
2 IN- Ground for input
The input contact activation is carried out by joining the corresponding line (IN+) with the common (IN-).
The opto-isolated input internal electrical scheme of is shown in the following figure:
Figure 5. Electrical scheme of the input contact
1.10 Output contact connector
The output contact is a free-of-voltage dry contact between the two male connector terminals (
in Figure
4):
Pin Signal Description
1 OUT_A Output A
2 OUT_B Output B
This contact supports a maximum current of 1A.
The internal structure of the “normally open” relay output is the one shown in Figure 6.
9
8
7
Przeglądanie stron 10
1 2 ... 6 7 8 9 10 11 12 13 14 15 16 ... 32 33

Komentarze do niniejszej Instrukcji

Brak uwag